EPEVER Photo voltaic CHARGE CONTROLLER SETUP: TRACER AN SERIES CONTROLLE

The EPEVER Tracer AN Series Photo voltaic Charge Controller is often a very efficient solar controller created for off-grid photo voltaic methods. According to multiphase synchronous rectification technologies, it ensures optimized Strength conversion and procedure security for a wide array of photovoltaic (PV) applications.

Essential Options of the EPEVER Tracer AN Sequence Controller
The Tracer AN series makes use of EPEVER Photo voltaic Charge Controller engineering for outstanding photo voltaic energy harvesting. Crucial characteristics incorporate:

Multiphase Synchronous Rectification (MSR) for enhanced Electricity conversion.
Highly developed MPPT Algorithm with >ninety nine% performance.
Twin-Phase Charging for Improved battery lifetime.
Liquid crystal display Display screen with serious-time data monitoring.
Many Load Regulate Modes like manual and timer.
Extensive Electronic Protections from overcharging, in excess of-discharging, limited circuits, and reverse polarity.
Phase-by-Phase Guidebook to Creating the EPEVER Tracer AN Series Controller
1. Unboxing and Making ready the Controller
Be certain all factors are bundled: Tracer AN device, temperature sensor, interaction cables, and consumer guide.
Verify the design number and voltage scores match your photo voltaic panel and battery requirements.
2. Mounting the Charge Controller
Select a perfectly-ventilated, dry site near to the battery financial institution.
Secure the Tracer AN controller utilizing the furnished mounting brackets.
Keep appropriate clearance for heat dissipation.
three. Wiring the Photo voltaic Cost Controller
Caution: Normally observe suitable security protocols and ensure the procedure is driven off before connecting factors.

Move one: Join the battery terminals for the charge controller (favourable to beneficial, damaging to damaging).
Step two: Link the photo voltaic panel array on the PV input terminals.
Move three: Link the load terminals if employing a immediate load connection.
Move 4: Double-Verify all connections for polarity and tightness.
four. Configuring the Controller Options
Energy over the controller by connecting the battery initially.
Make use of the LCD Exhibit to navigate the options menu.
Configure:
Battery Type: AGM, GEL, Flooded, Lithium.
Charging Parameters: Absorption voltage, float voltage.
Load Manage Modes: Manual, timer, light-weight Management.
5. Checking and Info Logging
The Tracer AN Series supports authentic-time monitoring utilizing the MT50 distant meter.
Data is often logged through the RS485 communication port working with computer software such as Photo voltaic Station Computer.
Distant monitoring can be done With all the EPEVER WiFi module.
six. Troubleshooting Frequent Issues
Problem one: No Electrical power Output

Look at battery voltage and connections.
Confirm PV panel voltage exceeds battery voltage.
Situation 2: Around-Voltage Safety

Validate the solar array’s voltage ranking.
Modify process parameters if required.
Difficulty 3: No Battery Charging

Inspect PV wiring for continuity.
Ensure MPPT settings from the menu.
Benefits of the Tracer AN Sequence with MSR Read more Technology
The multiphase synchronous rectification know-how ensures:

Increased Efficiency: Lowered Electrical power losses in the course of conversion.
Increased Reliability: Steady performance beneath variable hundreds.
Lengthier Battery Lifetime: Consistent and correct charging profiles.
Summary
The EPEVER Solar Demand Controller with multiphase synchronous rectification technological innovation is an Excellent option for optimizing solar power generation and lengthening battery lifetime. By following the above setup guideline, customers can guarantee most efficiency and program longevity.